IDI - Irish Decontamination Institute...

IDI - Irish Decontamination Institute

NOTE: These WFHSS web archive pages are not maintained anymore. Please visit wfhss.com for current WFHSS affairs.
/ IDI - Irish Decontamination Institute / Publications / Periodicals / Central Service / Central Service Archive / Central Service 5/2000
Central Service - Issue 5/2000

Central Service - Issue 5/2000

EDITORIAL

How far is too far?

NEWS UPDATE

  • What's New in Standardisation: Alternative Indicators for the Bowie & Dick Test
  • Erratum: Desorption of Ethylene Oxide (Issue no. 4/2000)
  • How Clean are Surgical Instruments in German Hospitals? A multi-centre trial provides an insight
  • Temporary Injunction against BVMed Leaflet
  • E-Commerce in the Healthcare Market: Major Potential Savings
  • Potsdam and the DGSV - A Synthesis of the Arts.
  • Congress of the German Society for Sterile Supply (DGSV) 1 - 3 October 2000

MAIN ARTICLES

S. Meurer, T. Arnold, E. Dennhöfer, R. Peter

Abstract
Critical Size of Test Pack for Steam Sterilisers with Chamber Volume of 80 Liters

J. Gömann, U. Kaiser, R. Menzel:
Reaction Kinetics of the Low-Temperature-Steam-Formaldehyde (LTSF) Sterilisation Process
Characterisation of Biological Indicators for Validation and Routine Monitoring

Abstract
The kinetics of the low temperature steam formaldehyde sterilisation process has been described. A method for resistance determination for validation and monitoring of the LTSF process and resistance specifications for suitable biological indicators have been proposed.

FORUM

H. Pahlke:
Investigation of the Bowie & Dick Test Programme with the ebro BD-Logger

Abstract
One of the most important daily functional checks for any steam steriliser is the steam penetration test, the Bowie & Dick test (B&D test). The standard test pack as per EN 285 or indicators as per DIN EN 867 can be used for testing.
Using a highly precise measuring instrument, the Bowie-Dick Logger manufactured by ebro Electronic GmbH & Co. KG, the parameters of the Bowie & Dick test programme were checked for 3 sterilisers in a hospital. For all measurements in the 3 sterilisers It was possible to furnish proof on using the Bowie-Dick Datalogger that the specifications of the B&D test manufacturer as outlined in the standard were not complied with. For the user this means that there is no legal safety due to the lack of parameter compliance.
In summary, it can be stated that on using this BD-Datalogger correct implementation of a B&D test can be documented. The parameters should be checked weekly.

EDUCATION

P. Heeg:
Tuberculosis (2)

MAILBOX

Just-in-time delivery system

RECOMMENDATIONS BY THE QUALITY TASK GROUP (AK »QUALITÄT«)

Quality Assurance on the "Clean Side" of a CSSD


Publisher
Information on this page provided with kind permission of: mhp-verlag GmbH
Address: Marktplatz 13
65183 Wiesbaden
Germany
Phone: +49-(0)611-50593 0
Fax: +49-(0)611-50593 11
Web: www.mhp-verlag.de
E-mail:

mhp stands for publications in medicine, hygiene and prevention. For more than 20 years, the mhp publishing house has devoted itself to supporting developments aiming for a better standard of hygiene and infection control in hospitals and other medical facilities.

Free Access to Central Service E-Paper
Since 2008 Central Service has also been available as electronic E-Paper version. Subscriptions are possible to the print issue only, the online E-Paper issue only, or as a combined subscription to both. A free E-Paper version of back issues of Central Service is now available for subscribers to the print issue (starting from Volume 16, 2008). Please contact to order your free E-Paper access code.

Archive